PLC POWER LINE CONDITIONER

POWERTRONIX has taken power protection one step further with the release of its new line of low impedance power conditioners. Using only the highest quality UL and CSA approved components, POWERTRONIX PLCs will ensure the best protection for sensitive electronic equipment.

POWERTRONIX low impedance PLCs assure tight voltage regulation, completely eliminate ground-loop problems, greatly reduce EMI and RFI, and insulate connected equipment against potentially harmful leakage currents.

A variety of voltage ratings, enclosures, connectors, and features (such as over-temperature protection, ground-fault interruption, and soft start) are available.

APPLICATIONS:
POWERTRONIX PLCs are used with medical and dental instruments, computer systems, automatic test equipment, and telecommunications systems, among others.

Picture
Picture

SPECIFICATIONS

 

. Input Voltage:

120 V or 230 V

. Frequency:

47 Hz - 63 Hz

. Isolation:

4,000 VRMS

. Output Voltage:

120 V or 230 V

. Power Range:

500 VA - 5,000 VA

. Efficiency:

98% - 95%

SAFETY APPROVALS

BUILT TO

. UL 2601

. IEC 601.1

. CSA 22.2, No. 66

. VDE 750 Part 1

. CE Marking

. CSA 22.2, No. 601.1-M90

Model
Number

Power
(VA)

Dimensions
L x W x H

Weight
(lbs)

PLC 0500

0500

11" x 8" x 5.2"

15

PLC 1000

1000

11" x 8" x 5.2"

21

PLC 1500

1500

12" x 11" x 5.2"

27

PLC 2000

2000

12" x 11" x 5.2"

32

PLC 2500

2500

17" x 11" x 5.2"

40

PLC 3000

3000

17" x 11" x 5.2"

49

PLC 4000

4000

17" x 11" x 5.2"

60

PLC 5000

5000

17" x 11" x 5.2"

66

Picture

For grayed out items consult your Powertronix representative

A    EMERGENCY CIRCUIT BREAKER
A breaker that will cut power to the PDIMU and its output in the event of an emergency. As a safety precaution, the unit can only be restarted by powering the system off (from the AC mains) and re-booting, once this breaker has been tripped.

B    CIRCUIT BREAKER
A 2-pole, current limiting, rocker type on/off breaker for standard operation.

C    INPUT PROTECTION
In order to assure the safety of the PDIMU and its load, this component protects the input from short circuit conditions on the output. In addition, it provides protection from ground fault interruptions that can lead to dangerous line-to-ground and shock hazard currents, as well as electrical fires.

D    SOFT START
A standard feature in all POWERTRONIX PDIMUs with a power rating greater than 2 kVA. It facilitates a smooth start up, by restraining damaging in-rush currents.

*     ISOLATION TRANSFORMER/FILTER
This is the core of the POWERTRONIX PDIMU, and it incorporates components E and F that provide over-temperature protection and low frequency noise suppression, respectively. Components E and F are integrated within a low impedance, highly insulated and well-shielded POWERTRONIX Toroidal Transformer, which itself eliminates ground-loop problems, insulates connected equipment against potentially harmful leakage currents, and provides extended brownout range.

E     THERMAL PROTECTION
A resetable thermal switch that automatically shuts off the power to the unit and connected equipment at a set temperature. The shut off temperature is based on the class of insulation in the toroidal transformer, as well as the application for which the unit is intended. Typically, the switch will trip at 110°C, and allow for restart once the unit has cooled down to approximately 70°C.

F     NON-LINEAR FILTER
This element prevents low frequency noise (<3 kHz) from reaching the sensitive load.

G    HIGH FREQUENCY SUPPRESSION
This module limits EMI and RFI, in addition to other high frequency noise
(2.5 kHz to 300MHz), from reaching the sensitive load.

H    SEQUENTIAL LOAD DISTRIBUTION
This feature limits the amount of strain placed on the PDIMU at start up, and extends added protection to connected equipment. Output receptacles are activated sequentially. Each output (following the first) is restrained until the current on the previous one has gone beyond its peak value and has decayed to a steady state value.

All data are typical values and subject to change without prior notice.

Industrial grade isolation units are also available for applications that do not require
UL 2601 approval and where a leakage current of more than 100 µA is acceptable.

Custom designed Medical Isolation Units are also available!

Powertronix  .  1120 Chess Drive, Foster City, CA 94404
Tel:  (650) 345-6800  .  Fax: (650) 345-7240